Technická data
Název:
SIPLUS CMS2000 Basic Unit VIB
Popis:
SIPLUS CMS2000 - BASIC UNIT VIB; 2 IEPE VIBRATION ACCELERATION CHANNELS; 2 ANALOGE INPUTS FOR PROCESS VALUES; 1 DIGITAL INPUT FOR ROTATION SPEED MEASUREMENT; 3 DIGITAL OUTPUTS FOR SYSTEM- AND LIMIT MONITORING
Technické informace:
General information | ||
Product brand name | SIPLUS | |
Product designation | SIPLUS CMS2000 Basic Unit VIB | |
Product description | Basic unit for the monitoring of vibrations on mechanical components based on parameters and frequency-selective analysis functions for measuring category 0 acc. to EN 61010 | |
Physical measuring principle | Vibration acceleration | |
Measurement range vibration frequency, min. | 2 Hz | |
Measurement range vibration frequency, max. | 10 000 Hz | |
Installation type/mounting | ||
Mounting type | standard rail | |
Mounting position | vertical | |
Recommended mounting position | vertical | |
Supply voltage | ||
Type of supply voltage | DC | |
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | |
Power loss | ||
Power loss, typ. | 2.6 W | |
Memory | ||
Total memory capacity | 1 Gbyte | |
Hardware configuration | ||
Design of hardware configuration | modular construction, basic unit can be expanded by means of expansion modules | |
Digital inputs | ||
Number of disable inputs | 1 | |
Number of trigger inputs | 1 | |
Input voltage | ||
● At the 24 V DC disable input | Yes | |
● At the disable input (DC), max. | 28.8 V | |
● At the trigger input 24 V DC | Yes | |
● At the trigger input (DC), max. | 28.8 V | |
Digital outputs | ||
Number of signaling outputs | 3 | |
Design of signaling outputs | Electronic | |
Output current | ||
● For signaling output, max. | 0.1 A | |
Analog inputs | ||
Number of analog inputs | 2 | |
Input ranges (rated values), voltages | ||
● At DC, min. | -10 V | |
Input ranges (rated values), currents | ||
● 0 to 20 mA | No | |
● +/- 4 mA to +/- 20 mA | Yes | |
Speed input | ||
Number of speed inputs | 1 | |
Protocols | ||
● 24 V DC digital | Yes | |
● At DC, max. | 28.8 V | |
● -10 V to +10 V | No | |
Protocols | ||
● 0 to 20 mA | No | |
● 4 mA to 20 mA | No | |
● permissible range, upper limit | 0.1 A | |
● Short-circuit current | 0.7 A | |
Sensor input | ||
Number of IEPE sensor inputs | 2 | |
Number of MEMS sensor inputs | 0 | |
Sampling frequency, max. | 46 875 Hz | |
Interfaces | ||
Type of data transmission | Exporting of raw data as WAV file for further analyses (e.g. using CMS X-Tools) can be downloaded via browser | |
Ethernet interface | Yes | |
SIMOCODE interface | Yes | |
Protocols | ||
Bus communication | Yes | |
Open IE communication | ||
● TCP/IP | Yes | |
Web server | ||
● HTTP | Yes | |
Interrupts/diagnostics/status information | ||
Diagnostics via e-mail | Yes | |
Integrated Functions | ||
Monitoring functions | ||
● Monitoring of the sensor inputs | Yes | |
● Vibration characteristic monitoring via RMS value of the vibration speed | Yes | |
● Vibration characteristic monitoring via diagnostic characteristic value | Yes | |
● Frequency-selective monitoring via vibration speed spectrum | Yes | |
● Frequency-selective monitoring via vibration acceleration spectrum | Yes | |
● Frequency-selective monitoring via envelope curve analysis | Yes | |
Isolation | ||
Overvoltage category | II | |
Degree and class of protection | ||
IP degree of protection | IP20 | |
Standards, approvals, certificates | ||
Certificate of suitability | CE, UL 508, CSA C22.2 Nr.142, C-TICK (RCM) | |
CE mark | Yes | |
RCM (formerly C-TICK) | Yes | |
KC approval | Yes | |
EAC (formerly Gost-R) | Yes | |
China RoHS compliance | Yes | |
Degree of pollution | 2 | |
Equipment marking according to EN 61346-2 | P | |
Equipment marking according to DIN 40719, expanded according to IEC 204-2, according to IEC 750 | P | |
Ambient conditions | ||
Ambient temperature during operation | ||
● min. | -20 °C | |
● max. | 65 °C | |
Ambient temperature during storage/transportation | ||
● Storage, min. | -25 °C | |
● Storage, max. | 85 °C | |
● Transportation, min. | -25 °C | |
● Transportation, max. | 85 °C | |
Air pressure acc. to IEC 60068-2-13 | ||
● Installation altitude above sea level, max. | 1 500 m | |
Relative humidity | ||
● Operation without condensation, min. | 5 % | |
● Operation without condensation, max. | 95 % | |
Software | ||
Browser software required | Webbrowser Mozilla Firefox, Google Chrome or Microsoft Internet Explorer | |
Connection method | ||
Design of electrical connection for the inputs and outputs | Screw connection | |
Design of electrical connection for auxiliary and control circuit | Screw connection | |
● Connectable conductor cross-section, solid or stranded, min. | 0.5 mm² | |
● Connectable conductor cross-section, solid or stranded, max. | 4 mm² | |
● Connectable conductor cross-section, finely stranded with end sleeve, min. | 0.5 mm² | |
● Connectable conductor cross-section, finely stranded with end sleeve, max. | 2.5 mm² | |
● Connectable cable cross-section finely stranded without end sleeve, min. | 0.5 mm² | |
● Connectable cable cross-section finely stranded without end sleeve, max. | 2.5 mm² | |
Terminals | ||
● Removable terminal for main circuit | Yes | |
● Removable terminal for auxiliary and control circuit | Yes | |
Mechanics/material | ||
Material of housing | plastic | |
Dimensions | ||
Width | 45 mm | |
Height | 106 mm | |
Depth | 124 mm | |
Weights | ||
Weight | 300 g | |
last modified: | 02/01/2017 |