Technická data
Název:
SIPLUS NET CP 443-1
Popis:
SIPLUS NET CP443-1 FOR MEDIAL STRESS WITH CONFORMAL COATING BASED ON 6GK7443-1EX30-0XE0 . 2 X 10/100 MBIT/S (IE SWITCH); RJ 45 PORTS; ISO; TCP; UDP; PROFINET-IO CONTROLLER; S7-COMMUNCATION; OPEN COMMUNICATION (SEND/RE- CEIVE); S7-ROUTING; IP-CONFIGU- RATION VIA DHCP/BLOCK; IP ACCESSS CONTROL LIST; TIME- SYNCHRONISATION; EXTENDED WEB-DIAGNOSIS; FAST STARTUP; PROFIENERGY SUPPORT
Technické informace:
Product type designation | SIPLUS NET CP 443-1 | |
Transmission rate | ||
Transfer rate | ||
● at the 1st interface | 10 ... 100 Mbit/s | |
Interfaces | ||
Number of interfaces / acc. to Industrial Ethernet | 2 | |
Number of electrical connections | ||
● at the 1st interface / acc. to Industrial Ethernet | 2 | |
Type of electrical connection | ||
● at the 1st interface / acc. to Industrial Ethernet | RJ45 port | |
design of the removable storage / C-PLUG | No | |
Supply voltage, current consumption, power loss | ||
Type of voltage / of the supply voltage | DC | |
Supply voltage / 1 / from backplane bus | 5 V | |
Relative symmetrical tolerance / at DC | ||
● at 5 V | 5 % | |
Consumed current | ||
● from backplane bus / at DC / at 5 V / typical | 1.4 A | |
Power loss [W] | 8.6 W | |
Permitted ambient conditions | ||
Ambient temperature | ||
● during operation | 0 ... 60 °C | |
● during storage | -40 ... +70 °C | |
● during transport | -40 ... +70 °C | |
Ambient condition / relating to ambient temperature - air pressure - installation altitude | -25 ... +70°C at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // -25 ... +60°C at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // -25 ... +50°C at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | |
Relative humidity / with condensation / maximum | 100 %; r.F., incl. condensation/frost permitted (no commissioning in bedewed state) | |
Resistance to biologically active substances | ||
● conformity acc. to EN 60721-3-3 | Yes; Compliance with EN 60721-3-3, Class 3B2 mold, fungus, and sponge spores (except fauna). The supplied plug covers must remain in place over the unused interfaces during operation! | |
Resistance to chemically active substances | ||
● conformity acc. to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3). The supplied plug covers must remain in place over the unused interfaces during operation! | |
Resistance to mechanically active substances | ||
● conformity acc. to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation! | |
Protection class IP | IP20 | |
Design, dimensions and weight | ||
Module format | Compact module S7-400 single width | |
Width | 25 mm | |
Height | 290 mm | |
Depth | 210 mm | |
Net weight | 0.7 kg | |
Product properties, functions, components / general | ||
Number of units | ||
● per CPU / maximum | 14 | |
● Note | max. 4 as PN IO ctrl. | |
Performance data / open communication | ||
Number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum | 64 | |
Amount of data | ||
● as user data per ISO connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 8 Kibyte | |
● as user data per ISO on TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 8 Kibyte | |
● as user data per TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum | 8 Kibyte | |
● as user data per UDP connection / for open IE communication / by means of SEND/RECEIVE blocks / maximum | 2 Kibyte | |
Number of possible connections / for open communication | ||
● by means of T blocks / maximum | 64 | |
Amount of data | ||
● as user data per ISO on TCP connection / for open communication / by means of T blocks / maximum | 1452 byte | |
Performance data / S7 communication | ||
Number of possible connections / for S7 communication | ||
● maximum | 128 | |
● with PG connections / maximum | 2 | |
● Note | when using several CPUs | |
Performance data / multi-protocol mode | ||
Number of active connections / with multi-protocol mode | 128 | |
Performance data / PROFINET communication / as PN IO-Controller | ||
Product function / PROFINET IO controller | Yes | |
Number of PN IO devices / on PROFINET IO controller / usable / total | 128 | |
Number of PN IO IRT devices / on PROFINET IO controller / usable | 64 | |
Number of external PN IO lines / with PROFINET / per rack | 4 | |
Amount of data | ||
● as user data for input variables / as PROFINET IO controller / maximum | 4 Kibyte | |
● as user data for input variables / as PROFINET IO controller / maximum | 4 Kibyte | |
● as user data for input variables per PN IO device / as PROFINET IO controller / maximum | 1433 byte | |
● as user data for output variables per PN IO device / as PROFINET IO controller / maximum | 1433 byte | |
● as user data for input variables per PN IO device / for each sub-module as PROFINET IO controller / maximum | 240 byte | |
● as user data for output variables per PN IO device / for each sub-module as PROFINET IO controller / maximum | 240 byte | |
Performance data / telecontrol | ||
Protocol / is supported | ||
● TCP/IP | Yes | |
Product function / MIB support | Yes | |
Protocol / is supported | ||
● SNMP v1 | Yes | |
● DCP | Yes | |
● LLDP | Yes | |
Configuration software | ||
● required | STEP 7 V5.5 SP3 or higher / STEP 7 Professional V12 (TIA Portal) or higher | |
Product functions / Diagnosis | ||
Product function / Web-based diagnostics | Yes | |
Product functions / switch | ||
Product feature / Switch | Yes | |
Product function | ||
● switch-managed | No | |
● with IRT / PROFINET IO switch | Yes | |
● Configuration with STEP 7 | Yes | |
Product functions / Redundancy | ||
Product function | ||
● Ring redundancy | Yes | |
● Redundancy manager | Yes | |
Protocol / is supported / Media Redundancy Protocol (MRP) | Yes | |
Further Information / Internet Links | ||
Internet-Link | ||
● to website: Selector SIMATIC NET SELECTION TOOL | http://www.siemens.com/snst | |
● to website: Industrial communication | http://www.siemens.com/simatic-net | |
● to website: Industry Mall | https://mall.industry.siemens.com | |
● to website: Information and Download Center | http://www.siemens.com/industry/infocenter | |
● to website: Image database | http://automation.siemens.com/bilddb | |
● to website: CAx Download Manager | http://www.siemens.com/cax | |
● to website: Industry Online Support | https://support.industry.siemens.com | |
Security information | ||
Security information | Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action(e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4) | |
last modified: | 01/30/2017 |