Technická data
Název:
SIPLUS_ET200S 1Count 24V
Popis:
SIPLUS ET200S EM 1COUNT 24V/100 -25 ... +60 DGR C BASED-ON 6ES7138-4DA04-0AB0
Technické informace:
Supply voltage | ||
Load voltage L+ | ||
● Rated value (DC) | 24 V | |
● permissible range, lower limit (DC) | 20.4 V | |
● permissible range, upper limit (DC) | 28.8 V | |
● Reverse polarity protection | Yes | |
Input current | ||
from load voltage L+ (without load), max. | 42 mA | |
from backplane bus 3.3 V DC, max. | 10 mA | |
Encoder supply | ||
24 V encoder supply | ||
● 24 V | Yes; L+ (-0.8 V) | |
● Short-circuit protection | Yes | |
● Output current, max. | 500 mA | |
Power loss | ||
Power loss, typ. | 1 W | |
Hardware configuration | ||
Module exchange | ||
● Module exchange during operation of the IM-DP | Yes | |
● Module exchange under process voltage | Yes | |
Digital inputs | ||
Number of digital inputs | 1 | |
Functions | Gate control, synchronization, latch function | |
Input characteristic curve in accordance with IEC 61131, type 2 | Yes | |
Input voltage | ||
● Rated value (DC) | 24 V | |
● for signal "0" | -30 to +5V | |
● for signal "1" | +11 to +30V | |
Input current | ||
● for signal "0", max. (permissible quiescent current) | 2 mA | |
● for signal "1", typ. | 9 mA | |
Input delay (for rated value of input voltage) | ||
for standard inputs | ||
— at "0" to "1", max. | 2.5 µs; Filter off: 2.5 µs (200 kHz), filter on: 25 µs (20 kHz) | |
Cable length | ||
● shielded, max. | 100 m; Filter 20 kHz: 100 m, filter 200 kHz: 50 m | |
Digital outputs | ||
Number of digital outputs | 1 | |
Short-circuit protection | Yes | |
● Response threshold, typ. | 2.6 A to 4 A | |
Limitation of inductive shutdown voltage to | L+ (-50 to -60 V) | |
Controlling a digital input | Yes | |
Switching capacity of the outputs | ||
● on lamp load, max. | 5 W | |
Output voltage | ||
● Rated value (DC) | 24 V | |
● for signal "0", max. | 3 V | |
● for signal "1", min. | L+ (-1 V) | |
Output current | ||
● for signal "1" permissible range for 0 to 40 °C, min. | 5 mA | |
● for signal "1" permissible range for 0 to 40 °C, max. | 2 000 mA | |
● for signal "1" permissible range for 0 to 60 °C, min. | 5 mA | |
● for signal "1" permissible range for 0 to 60 °C, max. | 500 mA; 1000 mA at 50 °C | |
● for signal "0" residual current, max. | 0.5 mA | |
Output delay with resistive load | ||
● "0" to "1", max. | 100 µs | |
Switching frequency | ||
● with resistive load, max. | 100 Hz | |
● with inductive load, max. | 2 Hz | |
● on lamp load, max. | 10 Hz | |
Cable length | ||
● shielded, max. | 1 000 m | |
● unshielded, max. | 600 m | |
Encoder | ||
Number of connectable encoders, max. | 1 | |
Connectable encoders | ||
● Incremental encoder (asymmetrical) | Yes | |
● 24 V initiator | Yes | |
● 2-wire sensor | Yes | |
Interrupts/diagnostics/status information | ||
Diagnostic functions | Yes | |
Diagnostics indication LED | ||
● Group error SF (red) | Yes | |
● Status indicator digital input (green) | Yes | |
● Status indicator digital output (green) | Yes | |
● Status indicator backward counting (green) | Yes | |
● Status indicator forward counting (green) | Yes | |
Integrated Functions | ||
Measuring functions | ||
Measuring range | ||
— Frequency measurement, min. | 0.1 Hz | |
— Frequency measurement, max. | 100 kHz | |
— Cycle duration measurement, min. | 10 µs | |
— Cycle duration measurement, max. | 120 s | |
— Speed measurement, min. | 1 1/min | |
— Speed measurement, max. | 25 000 1/min | |
Counter | ||
Number of counter inputs | 1; 32 bit | |
Minimum pulse width | 2.5 µs; Filter off: 2.5 µs (200 kHz), filter on: 25 µs (20 kHz) | |
Parameter | ||
Remark | 16 byte | |
Potential separation | ||
Potential separation digital inputs | ||
● Potential separation digital inputs | No; only opposite shielding | |
Potential separation counter | ||
● between the channels and backplane bus | Yes | |
● Between the channels and load voltage L+ | No | |
Ambient conditions | ||
Extended ambient conditions | ||
● relative to ambient temperature-atmospheric pressure-installation altitude | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | |
Relative humidity | ||
— With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions) | |
Resistance | ||
— against biologically active substances / conformity with EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | |
— against chemically active substances / conformity with EN 60721-3-3 | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | |
— against mechanically active substances / conformity with EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | |
Dimensions | ||
Width | 15 mm | |
Height | 81 mm | |
Depth | 52 mm | |
Weights | ||
Weight, approx. | 40 g | |
last modified: | 02/01/2017 |