Technická data
Název:
SIPLUS ET200S EM 2 Pulse
Popis:
SIPLUS ET200S EM 2 PULSE -25 ... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7138-4DD01-0AB0 . ELECTRONIC MODULE 2 PULSE PULSEGENERATOR AND TIMER MODULE, 15 MM WIDE, 2 CHANNELS
Technické informace:
Supply voltage | ||
Load voltage L+ | ||
● Rated value (DC) | 24 V; From power module | |
● Reverse polarity protection | Yes | |
Input current | ||
from load voltage L+ (without load), max. | 40 mA | |
from backplane bus 3.3 V DC, max. | 10 mA | |
Encoder supply | ||
Type of output voltage | L+ (-0.8 V) | |
Short-circuit protection | Yes | |
Output current | ||
● Rated value | 500 mA | |
Power loss | ||
Power loss, typ. | 1.8 W | |
Digital inputs | ||
Number of digital inputs | 2 | |
Input characteristic curve in accordance with IEC 61131, type 2 | Yes | |
Input voltage | ||
● Rated value (DC) | 24 V | |
● for signal "0" | -30 to +5V | |
● for signal "1" | +11 to +30V | |
Input current | ||
● for signal "1", typ. | 9 mA | |
Input delay (for rated value of input voltage) | ||
● Input frequency (with a time delay of 0.1 ms), max. | 20 kHz | |
● Minimum pulse width for program reactions | 100 µs | |
Cable length | ||
● shielded, max. | 100 m | |
Digital outputs | ||
Number of digital outputs | 2 | |
Short-circuit protection | Yes | |
● Response threshold, typ. | 10 A | |
Limitation of inductive shutdown voltage to | L+ (-50 to -65 V) | |
Controlling a digital input | Yes | |
Accuracy of pulse duration | +/- (time period x 100 ppm), +/-100 µs with a load <= 50 ohms | |
minimum pulse duration | 100 µs | |
Switching capacity of the outputs | ||
● on lamp load, max. | 10 W | |
Output voltage | ||
● for signal "1", min. | L+ (-1 V) | |
Output current | ||
● for signal "1" rated value | 2 A | |
● for signal "1" permissible range for 0 to 60 °C, min. | 7 mA | |
● for signal "1" permissible range for 0 to 60 °C, max. | 2 A | |
● for signal "0" residual current, max. | 0.5 mA | |
Output delay with resistive load | ||
● "0" to "1", max. | 100 µs | |
● "1" to "0", max. | 200 µs | |
Switching frequency | ||
● with resistive load, max. | 5 kHz | |
● with inductive load, max. | 2 Hz | |
● on lamp load, max. | 10 Hz | |
Cable length | ||
● shielded, max. | 1 000 m | |
● unshielded, max. | 600 m | |
Encoder | ||
Connectable encoders | ||
● 2-wire sensor | Yes | |
— permissible quiescent current (2-wire sensor), max. | 2 mA | |
Interrupts/diagnostics/status information | ||
Diagnostics indication LED | ||
● Group error SF (red) | Yes | |
● Status indicator digital input (green) | Yes | |
● Status indicator digital output (green) | Yes | |
Integrated Functions | ||
Pulse generator | ||
● Number of channels | 2; 1 digital input and 1 digital output per channel | |
Potential separation | ||
Potential separation digital inputs | ||
● between the channels | No | |
● between the channels and backplane bus | Yes | |
Potential separation digital outputs | ||
● between the channels | No | |
● between the channels and backplane bus | Yes | |
Permissible potential difference | ||
between different circuits | 75 V DC/60 V AC | |
Isolation | ||
Isolation tested with | 500 V DC | |
Ambient conditions | ||
Extended ambient conditions | ||
● relative to ambient temperature-atmospheric pressure-installation altitude | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | |
Relative humidity | ||
— With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | |
Resistance | ||
— against biologically active substances / conformity with EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | |
— against chemically active substances / conformity with EN 60721-3-3 | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | |
— against mechanically active substances / conformity with EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | |
Dimensions | ||
Width | 15 mm | |
Height | 81 mm | |
Depth | 52 mm | |
Weights | ||
Weight, approx. | 40 g | |
last modified: | 02/01/2017 |