Technická data
Název:
SIPLUS ET200S IM151-8F PN/DP
Popis:
SIPLUS ET200S IM151-8F PN/DP -25 ... +60 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7151-8FB01-0AB0 . CPU FOR ET200S, 256 KB WORKING MEMORY, INT. PROFINET INTERFACE (WITH THREE RJ45 PORTS) AS IO-CONTROLLER, W/O BATTERY MMC REQUIRED
Technické informace:
General information | ||
Hardware product version | 01 | |
Firmware version | V3.2 | |
Engineering with | ||
● Programming package | STEP 7 V5.5 or higher, Distributed Safety V5.4 SP4 | |
Supply voltage | ||
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 20.4 V | |
permissible range, upper limit (DC) | 28.8 V | |
Reverse polarity protection | Yes; against destruction | |
external protection for power supply lines (recommendation) | 24 V DC/16 A miniature circuit breaker with type B and C tripping characteristics. Note: A 24 V DC/16 A miniature circuit breaker with type B tripping characteristics trips before and with type C tripping characteristic after the device protection fuse. | |
Mains buffering | ||
● Mains/voltage failure stored energy time | 5 ms | |
Input current | ||
Inrush current, max. | 1.8 A; Typical | |
I²t | 0.13 A²·s | |
from supply voltage 1L+, max. | 352 mA; 426 mA with DP master module | |
Output current | ||
for backplane bus (5 V DC), max. | 700 mA | |
Power loss | ||
Power loss, typ. | 5.5 W | |
Memory | ||
Work memory | ||
● integrated | 256 kbyte; For program and data | |
● expandable | No | |
● Size of retentive memory for retentive data blocks | 64 kbyte | |
Load memory | ||
● Plug-in (MMC) | Yes | |
● Plug-in (MMC), max. | 8 Mbyte | |
● Data management on MMC (after last programming), min. | 10 y | |
Backup | ||
● present | Yes; Ensured by SIMATIC Micro Memory Card (maintenance-free) | |
CPU processing times | ||
for bit operations, typ. | 0.06 µs | |
for word operations, typ. | 0.12 µs | |
for fixed point arithmetic, typ. | 0.16 µs | |
for floating point arithmetic, typ. | 0.59 µs | |
CPU-blocks | ||
Number of blocks (total) | 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. | |
DB | ||
● Number, max. | 1 024; Number range: 1 to 16000 | |
● Size, max. | 64 kbyte | |
FB | ||
● Number, max. | 1 024; Number range: 0 to 7999 | |
● Size, max. | 64 kbyte | |
FC | ||
● Number, max. | 1 024; Number range: 0 to 7999 | |
● Size, max. | 64 kbyte | |
OB | ||
● Description | See S7-300 operation list | |
● Size, max. | 64 kbyte | |
● Number of free cycle OBs | 1; OB 1 | |
● Number of time alarm OBs | 1; OB 10 | |
● Number of delay alarm OBs | 2; OB 20, 21 | |
● Number of cyclic interrupt OBs | 4; OB 32, 33, 34, 35 | |
● Number of process alarm OBs | 1; OB 40 | |
● Number of DPV1 alarm OBs | 3; OB 55, 56, 57 | |
● Number of isochronous mode OBs | 1; OB 61; only for PROFINET | |
● Number of startup OBs | 1; OB 100 | |
● Number of asynchronous error OBs | 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for centralized I/O and PROFINET IO) | |
● Number of synchronous error OBs | 2; OB 121, 122 | |
Nesting depth | ||
● per priority class | 16 | |
● additional within an error OB | 4 | |
Counters, timers and their retentivity | ||
S7 counter | ||
● Number | 256 | |
Retentivity | ||
— adjustable | Yes | |
— lower limit | 0 | |
— upper limit | 255 | |
— preset | Z 0 to Z 7 | |
Counting range | ||
— can be set | Yes | |
— lower limit | 0 | |
— upper limit | 999 | |
IEC counter | ||
● present | Yes | |
● Type | SFB | |
● Number | Unlimited (limited only by RAM capacity) | |
S7 times | ||
● Number | 256 | |
Retentivity | ||
— adjustable | Yes | |
— lower limit | 0 | |
— upper limit | 255 | |
— preset | No retentivity | |
Time range | ||
— lower limit | 10 ms | |
— upper limit | 9 990 s | |
IEC timer | ||
● present | Yes | |
● Type | SFB | |
● Number | Unlimited (limited only by RAM capacity) | |
Data areas and their retentivity | ||
Flag | ||
● Number, max. | 256 byte | |
● Retentivity available | Yes | |
● Retentivity preset | MB 0 to MB 15 | |
● Number of clock memories | 8; 1 memory byte | |
Data blocks | ||
● Number, max. | 1 024; Number range: 1 to 16000 | |
● Size, max. | 64 kbyte | |
● Retentivity adjustable | Yes; via non-retain property on DB | |
● Retentivity preset | Yes | |
Local data | ||
● per priority class, max. | 32 768 byte; Max. 2048 bytes per block | |
Address area | ||
I/O address area | ||
● Inputs | 2 048 byte | |
● Outputs | 2 048 byte | |
of which distributed | ||
— Inputs | 2 048 byte | |
— Outputs | 2 048 byte | |
Process image | ||
● Inputs, adjustable | 2 048 byte | |
● Outputs, adjustable | 2 048 byte | |
● Inputs, default | 128 byte | |
● Outputs, default | 128 byte | |
Subprocess images | ||
● Number of subprocess images, max. | 1; With PROFINET IO, the length of the user data is limited to 1600 bytes | |
Digital channels | ||
● Inputs | 16 336 | |
— of which central | 496 | |
● Outputs | 16 336 | |
— of which central | 496 | |
Analog channels | ||
● Inputs | 1 021 | |
— of which central | 124 | |
● Outputs | 1 021 | |
— of which central | 124 | |
Hardware configuration | ||
Number of modules per system, max. | 63; Centralized | |
Mounting rail | ||
● Number of mounting rails that can be used | 1 | |
● Length of mounting rail, max. | Station width: <= 1 m or < 2 m | |
Time of day | ||
Clock | ||
● Hardware clock (real-time) | Yes | |
● retentive and synchronizable | Yes | |
● Backup time | 6 wk; At 40 °C ambient temperature, typically | |
● Deviation per day, max. | 10 s; Typ.: 2 s | |
● Behavior of the clock following POWER-ON | Clock continues running after POWER OFF | |
● Behavior of the clock following expiry of backup period | Clock continues to run with the time at which the power failure occurred | |
Operating hours counter | ||
● Number | 1 | |
● Number/Number range | 0 | |
● Range of values | 0 to 2^31 hours (when using SFC 101) | |
● Granularity | 1 hour | |
● retentive | Yes; Must be restarted at each restart | |
Clock synchronization | ||
● supported | Yes | |
● to MPI, master | No | |
● to MPI, slave | No | |
● to DP, master | Yes; With DP master module | |
● to DP, slave | Yes; With DP master module | |
● in AS, master | No | |
● in AS, slave | No | |
● on Ethernet via NTP | Yes; As client | |
Interfaces | ||
Number of PROFINET interfaces | 3 | |
Number of wireless interfaces | 0 | |
1. Interface | ||
Interface type | PROFINET | |
Physics | Ethernet | |
Isolated | Yes | |
automatic detection of transmission rate | Yes | |
Autonegotiation | Yes | |
Autocrossing | Yes | |
Change of IP address at runtime, supported | Yes | |
Interface types | ||
● Number of ports | 3; RJ45 | |
● integrated switch | Yes | |
Media redundancy | ||
● supported | Yes | |
● Switchover time on line break, typ. | 200 ms; PROFINET MRP | |
● Number of stations in the ring, max. | 50 | |
Functionality | ||
● MPI | No | |
● PROFINET IO Controller | Yes; Also simultaneously with IO-Device functionality | |
● PROFINET IO Device | Yes; Also simultaneously with IO Controller functionality | |
● PROFINET CBA | Yes | |
● PROFIBUS DP master | No | |
● PROFIBUS DP slave | No | |
● Open IE communication | Yes; Via TCP/IP, ISO on TCP, and UDP | |
● Web server | Yes | |
— Number of HTTP clients | 5 | |
● Point-to-point connection | No | |
PROFINET IO Controller | ||
● Transmission rate, max. | 100 Mbit/s; full duplex | |
Services | ||
— PG/OP communication | Yes | |
— Routing | Yes; With DP master module | |
— S7 communication | Yes; with loadable FBs | |
— Isochronous mode | Yes; OB 61; only for PROFINET IO | |
— Open IE communication | Yes; Via TCP/IP, ISO on TCP, and UDP | |
— IRT | Yes | |
— Shared device | Yes | |
— Prioritized startup | Yes | |
— Number of IO devices with prioritized startup, max. | 32 | |
— Number of connectable IO Devices, max. | 128 | |
— Of which IO devices with IRT, max. | 64 | |
— of which in line, max. | 64 | |
— Number of IO Devices with IRT and the option "high flexibility" | 128 | |
— of which in line, max. | 61 | |
— Number of connectable IO Devices for RT, max. | 128 | |
— of which in line, max. | 128 | |
— Activation/deactivation of IO Devices | Yes | |
— Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 | |
— IO Devices changing during operation (partner ports), supported | Yes | |
— Number of IO Devices per tool, max. | 8 | |
— Device replacement without swap medium | Yes | |
— Send cycles | 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option) | |
— Updating time | Minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the number of configured user data items. | |
— Updating times | 250 µs to 512 ms (depends on operating mode; for more details, refer to Operating Instructions, "Interface Module IM151-8 PN/DP CPU") | |
Address area | ||
— Inputs, max. | 2 kbyte | |
— Outputs, max. | 2 kbyte | |
— User data consistency, max. | 1 024 byte; with PROFINET I/O | |
PROFINET IO Device | ||
Services | ||
— PG/OP communication | Yes | |
— Routing | Yes | |
— S7 communication | Yes; with loadable FBs | |
— Isochronous mode | No | |
— Open IE communication | Yes; Via TCP/IP, ISO on TCP, and UDP | |
— IRT | Yes | |
— PROFIenergy | Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device | |
— Shared device | Yes | |
— Number of IO Controllers with shared device, max. | 2 | |
Transfer memory | ||
— Inputs, max. | 1 440 byte; Per IO Controller with shared device | |
— Outputs, max. | 1 440 byte; Per IO Controller with shared device | |
Submodules | ||
— Number, max. | 64 | |
— User data per submodule, max. | 1 024 byte | |
PROFINET CBA | ||
● acyclic transmission | Yes | |
● cyclic transmission | Yes | |
Open IE communication | ||
● Number of connections, max. | 8 | |
● Local port numbers used at the system end | 0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 | |
2. Interface | ||
Interface type | External interface via master module 6ES7138-4HA00-0AB0 | |
Physics | RS 485 | |
Isolated | Yes | |
Power supply to interface (15 to 30 V DC), max. | No | |
Functionality | ||
● MPI | No | |
● PROFINET IO Controller | No | |
● PROFINET IO Device | No | |
● PROFINET CBA | No | |
● PROFIBUS DP master | Yes | |
● PROFIBUS DP slave | No | |
● Open IE communication | No | |
● Web server | No | |
DP master | ||
● Transmission rate, max. | 12 Mbit/s | |
● Number of DP slaves, max. | 32; Per station | |
Services | ||
— PG/OP communication | Yes | |
— Routing | Yes | |
— Global data communication | No | |
— S7 basic communication | Yes; I blocks only | |
— S7 communication | Yes | |
— S7 communication, as client | No | |
— S7 communication, as server | Yes | |
— Equidistance | Yes | |
— Isochronous mode | No | |
— SYNC/FREEZE | Yes | |
— Activation/deactivation of DP slaves | Yes | |
— Number of DP slaves that can be simultaneously activated/deactivated, max. | 8 | |
— Direct data exchange (slave-to-slave communication) | Yes | |
— DPV1 | Yes | |
Address area | ||
— Inputs, max. | 2 048 byte | |
— Outputs, max. | 2 048 byte | |
User data per DP slave | ||
— Inputs, max. | 244 byte | |
— Outputs, max. | 244 byte | |
Isochronous mode | ||
Isochronous operation (application synchronized up to terminal) | No | |
Communication functions | ||
PG/OP communication | Yes | |
Data record routing | Yes; With DP master module | |
Global data communication | ||
● supported | No | |
S7 basic communication | ||
● supported | Yes; I blocks | |
● User data per job, max. | 76 byte | |
● User data per job (of which consistent), max. | 76 byte | |
S7 communication | ||
● supported | Yes | |
● as server | Yes | |
● as client | Yes; via integrated PROFINET interface and loadable FBs | |
● User data per job, max. | See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) | |
Open IE communication | ||
● TCP/IP | Yes; via integrated PROFINET interface and loadable FBs | |
— Number of connections, max. | 8 | |
— Data length for connection type 01H, max. | 1 460 byte | |
— Data length for connection type 11H, max. | 32 768 byte | |
— several passive connections per port, supported | Yes | |
● ISO-on-TCP (RFC1006) | Yes; via integrated PROFINET interface and loadable FBs | |
— Number of connections, max. | 8 | |
— Data length, max. | 32 768 byte | |
● UDP | Yes; via integrated PROFINET interface and loadable FBs | |
— Number of connections, max. | 8 | |
— Data length, max. | 1 472 byte | |
Web server | ||
● supported | Yes | |
● Number of HTTP clients | 5 | |
● User-defined websites | Yes | |
PROFINET CBA (at set setpoint communication load) | ||
● Setpoint for the CPU communication load | 50 % | |
● Number of remote interconnection partners | 32 | |
● Number of functions, master/slave | 30 | |
● Total of all master/slave connections | 1 000 | |
● Data length of all incoming connections master/slave, max. | 4 000 byte | |
● Data length of all outgoing connections master/slave, max. | 4 000 byte | |
● Number of device-internal and PROFIBUS interconnections | 500 | |
● Data length of device-internal und PROFIBUS interconnections, max. | 4 000 byte | |
● Data length per connection, max. | 1 400 byte | |
Remote interconnections with acyclic transmission | ||
— Sampling frequency: Sampling time, min. | 500 ms | |
— Number of incoming interconnections | 100 | |
— Number of outgoing interconnections | 100 | |
— Data length of all incoming interconnections, max. | 2 000 byte | |
— Data length of all outgoing interconnections, max. | 2 000 byte | |
— Data length per connection, max. | 1 400 byte | |
Remote interconnections with cyclic transmission | ||
— Transmission frequency: Transmission interval, min. | 1 ms | |
— Number of incoming interconnections | 200 | |
— Number of outgoing interconnections | 200 | |
— Data length of all incoming interconnections, max. | 2 000 byte | |
— Data length of all outgoing interconnections, max. | 2 000 byte | |
— Data length per connection, max. | 450 byte | |
HMI variables via PROFINET (acyclic) | ||
— Number of stations that can log on for HMI variables (PN OPC/iMap) | 3; 2x PN OPC/1x iMap | |
— HMI variable updating | 500 ms | |
— Number of HMI variables | 200 | |
— Data length of all HMI variables, max. | 2 000 byte | |
PROFIBUS proxy functionality | ||
— supported | Yes | |
— Number of linked PROFIBUS devices | 16 | |
— Data length per connection, max. | 240 byte; Slave-dependent | |
iPAR server | ||
● supported | Yes | |
Number of connections | ||
● overall | 12 | |
● usable for PG communication | 11 | |
— reserved for PG communication | 1 | |
— adjustable for PG communication, min. | 1 | |
— adjustable for PG communication, max. | 11 | |
● usable for OP communication | 11 | |
— reserved for OP communication | 1 | |
— adjustable for OP communication, min. | 1 | |
— adjustable for OP communication, max. | 11 | |
● usable for S7 basic communication | 10 | |
— reserved for S7 basic communication | 0 | |
— adjustable for S7 basic communication, min. | 0 | |
— adjustable for S7 basic communication, max. | 10 | |
● usable for S7 communication | 10; with loadable FBs | |
— adjustable for S7 communication, max. | 10 | |
● total number of instances, max. | 32 | |
● usable for routing | 4; max. | |
S7 message functions | ||
Number of login stations for message functions, max. | 12; Depending on the configured connections for PG/OP and S7 basic communication | |
Process diagnostic messages | Yes; ALARM_S, ALARM_SC, ALARM_SQ, ALARM_D, ALARM_DQ | |
simultaneously active Alarm-S blocks, max. | 300 | |
Test commissioning functions | ||
Status block | Yes; Up to 2 simultaneously | |
Single step | Yes | |
Number of breakpoints | 4 | |
Status/control | ||
● Status/control variable | Yes | |
● Variables | Inputs, outputs, memory bits, DB, times, counters | |
● Number of variables, max. | 30 | |
— of which status variables, max. | 30 | |
— of which control variables, max. | 14 | |
Forcing | ||
● Forcing | Yes | |
● Forcing, variables | I/O | |
● Number of variables, max. | 10 | |
Diagnostic buffer | ||
● present | Yes | |
● Number of entries, max. | 500 | |
— adjustable | No | |
— of which powerfail-proof | 100; Only the last 100 entries are retained | |
Interrupts/diagnostics/status information | ||
Alarms | Yes | |
Diagnostic functions | Yes | |
Diagnostics indication LED | ||
● Bus activity PROFINET P1-LINK (green) | Yes | |
● Bus activity PROFINET P2-LINK (green) | Yes | |
● Bus activity PROFINET P3-LINK (green) | Yes | |
● Bus fault BF-PN (red) | Yes | |
● Maintenance information MT (yellow) | Yes | |
● Group error SF (red) | Yes | |
● Monitoring 24 V voltage supply ON (green) | Yes | |
Potential separation | ||
between PROFIBUS DP and all other circuit components | Yes | |
Permissible potential difference | ||
between different circuits | 75 V DC/60 V AC | |
Isolation | ||
Isolation tested with | 500 V DC | |
Degree and class of protection | ||
IP degree of protection | IP20 | |
Standards, approvals, certificates | ||
CE mark | Yes | |
RCM (formerly C-TICK) | Yes | |
Ambient conditions | ||
Ambient temperature during operation | ||
● min. | -25 °C; = Tmin | |
● max. | 60 °C; = Tmax | |
Extended ambient conditions | ||
● relative to ambient temperature-atmospheric pressure-installation altitude | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) | |
Relative humidity | ||
— With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | |
Resistance | ||
— against biologically active substances / conformity with EN 60721-3-3 | Yes; Available soon | |
— against chemically active substances / conformity with EN 60721-3-3 | Yes; Available soon | |
— against mechanically active substances / conformity with EN 60721-3-3 | Yes; Available soon | |
Configuration | ||
Configuration software | ||
● STEP 7 | Yes; V5.5 or higher | |
Programming | ||
● Command set | see instruction list | |
● Nesting levels | 8 | |
● System functions (SFC) | see instruction list | |
● System function blocks (SFB) | see instruction list | |
Programming language | ||
— LAD | Yes | |
— FBD | Yes | |
— STL | Yes | |
— SCL | Yes; Optional | |
— CFC | Yes; Optional | |
— GRAPH | Yes; Optional | |
— HiGraph® | Yes; Optional | |
Know-how protection | ||
● User program protection/password protection | Yes | |
● Block encryption | Yes; With S7 block Privacy | |
Cycle time monitoring | ||
● lower limit | 1 ms | |
● upper limit | 6 000 ms | |
● adjustable | Yes | |
● preset | 150 ms | |
Dimensions | ||
Width | 120 mm; DP master module: 35 mm | |
Height | 119.5 mm | |
Depth | 75 mm | |
Weights | ||
Weight, approx. | 320 g; DP master module: Approx. 100 g | |
last modified: | 02/01/2017 |