Technická data
Název:
SIPLUS ET 200SP AQ 2 X U/I HIGH SPEED
Popis:
SIPLUS ET 200SP, ANALOGUE OUTPUT MODULE, AQ 2 X U/I HIGH SPEED, -40 ... +70 GRAD C WITH CONFORMAL COATING BASED ON 6ES7135-6HB00-0DA1 . FITS TO BU-TYP A0, A1, COLOR CODE CC00, CHANNEL DIAGNOSIS, 16BIT, +/-0,3%
Technické informace:
General information | ||
Product type designation | ET 200SP, AQ 2xU/I High Speed | |
Firmware version | V2.0 | |
usable BaseUnits | BU type A0, A1 | |
Color code for module-specific color identification plate | CC00 | |
Product function | ||
● I&M data | Yes; I&M0 to I&M3 | |
Engineering with | ||
● STEP 7 TIA Portal configurable/integrated as of version | V13 SP1 | |
● STEP 7 configurable/integrated as of version | V5.5 SP3 / - | |
● PROFIBUS as of GSD version/GSD revision | GSD Revision 5 | |
● PROFINET as of GSD version/GSD revision | GSDML V2.3 | |
Operating mode | ||
● Oversampling | Yes; 2 channels per module | |
● MSO | No | |
CiR – Configuration in RUN | ||
Reparameterization possible in RUN | Yes | |
Calibration possible in RUN | Yes | |
Supply voltage | ||
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | |
Reverse polarity protection | Yes | |
Input current | ||
Current consumption (rated value) | 45 mA; without load | |
Power loss | ||
Power loss, typ. | 0.9 W | |
Address area | ||
Address space per module | ||
● Address space per module, max. | 4 byte; + 1 byte for QI information (32 bytes in the oversampling operating mode) | |
Analog outputs | ||
Number of analog outputs | 2 | |
Voltage output, short-circuit protection | Yes | |
Voltage output, short-circuit current, max. | 45 mA | |
Cycle time (all channels), min. | 125 µs | |
Analog output with oversampling | Yes | |
● Values per cycle, max. | 16 | |
● Resolution, min. | 45 µs; (2 channels), 35 µs (1 channel) | |
Output ranges, voltage | ||
● 0 to 10 V | Yes; 15 bit | |
● 1 V to 5 V | Yes; 13 bit | |
● -5 V to +5 V | Yes; 15 bit incl. sign | |
● -10 V to +10 V | Yes; 16 bit incl. sign | |
Output ranges, current | ||
● 0 to 20 mA | Yes; 15 bit | |
● -20 mA to +20 mA | Yes; 16 bit incl. sign | |
● 4 mA to 20 mA | Yes; 14 bit | |
Connection of actuators | ||
● for voltage output two-wire connection | Yes | |
● for voltage output four-wire connection | Yes | |
● for current output two-wire connection | Yes | |
Load impedance (in rated range of output) | ||
● with voltage outputs, min. | 2 kΩ | |
● with voltage outputs, capacitive load, max. | 1 µF | |
● with current outputs, max. | 500 Ω | |
● with current outputs, inductive load, max. | 1 mH | |
Destruction limits against externally applied voltages and currents | ||
● Voltages at the outputs | 30 V | |
Cable length | ||
● shielded, max. | 1 000 m; 200 m for voltage output | |
Analog value generation for the outputs | ||
Settling time | ||
● for resistive load | 0.05 ms | |
● for capacitive load | 0.05 ms; Max. 47 nF and 20 m cable length | |
● for inductive load | 0.05 ms | |
Errors/accuracies | ||
Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-) | 0.02 % | |
Linearity error (relative to output range), (+/-) | 0.03 % | |
Temperature error (relative to output range), (+/-) | 0.003 %/K | |
Crosstalk between the outputs, max. | -50 dB | |
Repeat accuracy in steady state at 25 °C (relative to output range), (+/-) | 0.03 % | |
Operational error limit in overall temperature range | ||
● Voltage, relative to output range, (+/-) | 0.4 % | |
● Current, relative to output range, (+/-) | 0.4 % | |
Basic error limit (operational limit at 25 °C) | ||
● Voltage, relative to output range, (+/-) | 0.1 % | |
● Current, relative to output range, (+/-) | 0.1 % | |
Isochronous mode | ||
Isochronous operation (application synchronized up to terminal) | Yes | |
Execution and activation time (TCO), min. | 70 µs | |
Bus cycle time (TDP), min. | 125 µs | |
Interrupts/diagnostics/status information | ||
Diagnostics function | Yes | |
Substitute values connectable | Yes | |
Alarms | ||
● Diagnostic alarm | Yes | |
Diagnostic messages | ||
● Monitoring the supply voltage | Yes | |
● Wire-break | Yes; channel-by-channel, only for output type "current" | |
● Short-circuit | Yes; channel-by-channel, only for output type "voltage" | |
● Group error | Yes | |
● Overflow/underflow | Yes | |
Diagnostics indication LED | ||
● Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED | |
● Channel status display | Yes; Green LED | |
● for channel diagnostics | Yes; Red LED | |
● for module diagnostics | Yes; green/red DIAG LED | |
Potential separation | ||
Potential separation channels | ||
● between the channels | No | |
● between the channels and backplane bus | Yes | |
● between the channels and the power supply of the electronics | Yes | |
Permissible potential difference | ||
between different circuits | 75 V DC/60 V AC (base isolation) | |
Isolation | ||
Isolation tested with | 707 V DC (type test) | |
Ambient conditions | ||
Ambient temperature during operation | ||
● horizontal installation, min. | -40 °C; = Tmin; Startup @ -25 °C | |
● horizontal installation, max. | 60 °C; = Tmax | |
Extended ambient conditions | ||
● relative to ambient temperature-atmospheric pressure-installation altitude | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | |
Relative humidity | ||
— With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | |
Resistance | ||
— against biologically active substances / conformity with EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | |
— against chemically active substances / conformity with EN 60721-3-3 | Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | |
— against mechanically active substances / conformity with EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | |
Dimensions | ||
Width | 15 mm | |
Weights | ||
Weight, approx. | 31 g | |
last modified: | 02/01/2017 |