Technická data
Název:
SIPLUS ET 200SP F-RQ 24VDC/24-230VAC/5A
Popis:
SIPLUS ET 200SP F-RQ 24VDC/24-2 -25 ... +60 GRAD C STARTUP -25 GRAD C MIT CONFORMAL COATING BASED ON 6ES7136-6RA00-0BF0 . F-RQ 1X24VDC/24..230VAC/5A ST, 20MM WIDTH, 1 RELAY OUTPUT (2 NO-CONTACTS) TOTAL OUTPUT CURRENT 5A, RATED VOLTAGE DC 24V AND AC 24 .. 230V, USEABLE UP TO PL E (ISO13849-1: 2008)/ SIL 3 (IEC61508: 2010) IF CONTROLLED BY A F-DQ (E.G. 6AG1136-6DB00-2CA0)
Technické informace:
General information | ||
Product type designation | F-RQ 1x24VDC/24 ... 230VAC/5A | |
usable BaseUnits | BU type F0, BU20-P8+A4+0B | |
Color code for module-specific color identification plate | CC42 | |
Product function | ||
● I&M data | Yes; I&M0 to I&M3 | |
Engineering with | ||
● STEP 7 TIA Portal configurable/integrated as of version | V13 | |
● STEP 7 configurable/integrated as of version | V5.5 SP4 and higher | |
Supply voltage | ||
Rated value (DC) | 24 V; Coil voltage | |
permissible range, lower limit (DC) | 20.4 V | |
permissible range, upper limit (DC) | 28.8 V | |
Power | ||
Power available from the backplane bus | 100 mW | |
Power loss | ||
Power loss, typ. | 1 W | |
Address area | ||
Address space per module | ||
● Inputs | 1 byte | |
Digital outputs | ||
Number of digital outputs | 1 | |
Limitation of inductive shutdown voltage to | No | |
Controlling a digital input | Yes | |
Switching capacity of the outputs | ||
● with resistive load, max. | 5 A | |
● on lamp load, max. | 25 W | |
Switching frequency | ||
● with resistive load, max. | 2 Hz | |
● with inductive load, max. | 0.1 Hz; See data in manual | |
● with inductive load (acc. to IEC 60947-5-1, DC13), max. | 0.1 Hz | |
● with inductive load (acc. to IEC 60947-5-1, AC15), max. | 2 Hz | |
Total current of the outputs (per module) | ||
horizontal installation | ||
— up to 40 °C, max. | 5 A; Note derating data in the manual | |
— up to 50 °C, max. | 4 A; Note derating data in the manual | |
— up to 60 °C, max. | 3 A; Note derating data in the manual | |
vertical installation | ||
— up to 50 °C, max. | 3 A; Note derating data in the manual | |
Relay outputs | ||
● Number of relay outputs | 1; 2 NO contacts | |
● Rated supply voltage of relay coil L+ (DC) | 24 V | |
● Current consumption of relays (coil current of all relays), max. | 70 mA | |
● external protection for relay outputs | yes; 6 A, see data in manual | |
● Relay approved acc. to UL 508 | Yes; Pilot Duty B300, R300 | |
Switching capacity of contacts | ||
— with inductive load, max. | see additional description in the manual | |
— with resistive load, max. | see additional description in the manual | |
— Thermal continuous current, max. | 5 A | |
— Switching current, min. | 1 mA | |
— Switching current after exceeding 300 mA, min. | 10 mA | |
— Switching current after exceeding 300 mA, max. | 5 A | |
— Rated switching voltage (DC) | 24 V | |
— Rated switching voltage (AC) | 230 V | |
Cable length | ||
● shielded, max. | 500 m; for load contacts | |
● unshielded, max. | 300 m; for load contacts | |
● Control cable (input), max. | 10 m | |
Interrupts/diagnostics/status information | ||
Diagnostics function | yes, firmware update | |
Diagnostics indication LED | ||
● RUN LED | Yes; green/red DIAG LED | |
● Channel status display | Yes; Green LED | |
Potential separation | ||
Potential separation channels | ||
● between the channels | Yes; for SELV / PELV only | |
● between the channels and backplane bus | Yes | |
● between the channels and the power supply of the electronics | Yes | |
Permissible potential difference | ||
between channels and backplane bus/supply voltage | 250 V AC (reinforced insulation) | |
between backplane bus and supply voltage | 75 V DC/60 V AC | |
Isolation | ||
Isolation tested with | 2 545 V DC/2 s (routine test) | |
Overvoltage category | III | |
tested with | ||
● between channels and backplane bus/supply voltage | DC 2545 V 2 s (routine test), impulse voltage test DC 7200 V / 5 positive and 5 negative pulses (type test) | |
● between backplane bus and supply voltage | 707 V DC (type test) | |
Ambient conditions | ||
Ambient temperature during operation | ||
● horizontal installation, min. | -25 °C; = Tmin | |
● horizontal installation, max. | 60 °C; = Tmax | |
Extended ambient conditions | ||
● relative to ambient temperature-atmospheric pressure-installation altitude | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) | |
Relative humidity | ||
— With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | |
Resistance | ||
— against biologically active substances / conformity with EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | |
— against chemically active substances / conformity with EN 60721-3-3 | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | |
— against mechanically active substances / conformity with EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | |
Dimensions | ||
Width | 20 mm | |
Height | 72 mm | |
Depth | 55 mm | |
Weights | ||
Weight, approx. | 90 g | |
last modified: | 02/01/2017 |