Technická data
Název:
SIPLUS ET 200SP TM PULSE 2x24V
Popis:
SIPLUS ET 200SP -40 ... +60 GRAD C STARTUP TEMP.: -25 DEGREE C WITH CONFORMAL COATING BASEDON 6ES7138-6DB00-0BB1 . TM PULSE 2X24V, PWM AND PULSE OUTPUT, 2 CHANNELS 2 A. FOR VALVES AND DC MOTORS
Technické informace:
General information | ||
Product type designation | TM Pulse 2x24 V | |
Firmware version | V1.0 | |
● FW update possible | Yes | |
usable BaseUnits | BU type B1 | |
Color code for module-specific color identification plate | CC40 | |
Product function | ||
● I&M data | Yes; I&M 0 | |
● Isochronous mode | Yes | |
Engineering with | ||
● STEP 7 TIA Portal configurable/integrated as of version | V13 SP1 | |
● STEP 7 configurable/integrated as of version | V5.5 SP4 and higher | |
● PROFIBUS as of GSD version/GSD revision | GSD Revision 5 | |
● PROFINET as of GSD version/GSD revision | GSDML V2.31 | |
Supply voltage | ||
Load voltage L+ | ||
● Rated value (DC) | 24 V | |
● permissible range, lower limit (DC) | 19.2 V | |
● permissible range, upper limit (DC) | 28.8 V | |
● Short-circuit protection | Yes | |
● Reverse polarity protection | Yes; against destruction | |
Input current | ||
Current consumption, max. | 70 mA; without load | |
Encoder supply | ||
Number of outputs | 2; A common 24V encoder supply for both channels | |
24 V encoder supply | ||
● 24 V | Yes; L+ (-0.8 V) | |
● Short-circuit protection | Yes; per module, electronic | |
● Output current, max. | 300 mA | |
Power loss | ||
Power loss, typ. | 1.7 W | |
Address area | ||
Occupied address area | ||
● Inputs | 16 byte; 8 per channel | |
● Outputs | 24 byte; 12 per channel | |
Digital inputs | ||
Number of digital inputs | 2; 1 per channel | |
Digital inputs, parameterizable | Yes | |
Input characteristic curve in accordance with IEC 61131, type 3 | Yes | |
Digital input functions, parameterizable | ||
● Freely usable digital input | Yes | |
● HW enable for digital output | Yes | |
Input voltage | ||
● Type of input voltage | DC | |
● Rated value (DC) | 24 V | |
● for signal "0" | -30 to +5V | |
● for signal "1" | +11 to +30V | |
● permissible voltage at input, min. | -30 V | |
● permissible voltage at input, max. | 30 V | |
Input current | ||
● for signal "1", typ. | 2.5 mA | |
Input delay (for rated value of input voltage) | ||
for standard inputs | ||
— parameterizable | Yes; none / 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / 3.2 / 12.8 / 20 ms | |
— at "0" to "1", min. | 4 µs; for parameterization "none" | |
— at "1" to "0", min. | 4 µs; for parameterization "none" | |
Digital outputs | ||
Type of digital output | P- and M-switching | |
Number of digital outputs | 2; 1 per channel | |
Current-sinking | Yes | |
Current-sourcing | Yes | |
Digital outputs, parameterizable | Yes | |
Short-circuit protection | Yes; electronic/thermal | |
● Response threshold, typ. | 6.8 A with Standard output, 2 A with High Speed output | |
Limitation of inductive shutdown voltage to | -0.8 V | |
Controlling a digital input | Yes | |
Accuracy of pulse duration | ±100 ppm ±0.5 µs with High Speed output, ±100 ppm ±9 µs with Standard output | |
minimum pulse duration | 1.5 µs; With High Speed output, 10 µs with Standard output | |
Digital output functions, parameterizable | ||
● Freely usable digital output | Yes | |
● PWM output | Yes | |
— Number, max. | 2; 1 per channel | |
— Cycle duration, parameterizable | Yes; Max. 85 s | |
— ON period, min. | 0 % | |
— ON period, max. | 100 % | |
— Resolution of the duty cycle | 0.0036 %; For S7 analog format, min. 20 ns | |
● Connection of a proportional valve | Yes | |
● Dithering | Yes | |
— Frequency adjustable | Yes | |
— Amplitude adjustable | Yes | |
● Current measurement | Yes | |
● Current control | Yes | |
● Connection of a DC motor | Yes | |
● ON-delay | Yes | |
● OFF-delay | Yes | |
● Frequency output | Yes | |
● Pulse train | Yes | |
● Pulse output | Yes | |
Switching capacity of the outputs | ||
● with resistive load, max. | 2 A | |
● on lamp load, max. | 10 W; 1 W with High Speed output | |
Load resistance range | ||
● lower limit | 12 Ω; 240 ohm with High Speed output | |
● upper limit | 12 kΩ | |
Output voltage | ||
● Type of output voltage | DC | |
● for signal "0", max. | 1 V | |
● for signal "1", min. | 23.2 V; L+ (-0.8 V) | |
Output current | ||
● for signal "1" rated value | 2 A; 0.1 A with High Speed output, observe derating | |
Output delay with resistive load | ||
● "0" to "1", typ. | 0 µs; With High Speed output, 4.5 µs with Standard output | |
● "0" to "1", max. | 0.8 µs; With High Speed output, 9 µs with Standard output | |
● "1" to "0", typ. | 0 µs; With High Speed output, 4.5 µs with Standard output | |
● "1" to "0", max. | 0.8 µs; With High Speed output, 9 µs with Standard output | |
Parallel switching of two outputs | ||
● for uprating | Yes | |
Switching frequency | ||
● with resistive load, max. | 100 kHz; With High Speed output, 10 kHz with standard output | |
● with inductive load, max. | 100 kHz; With High Speed output, 10 kHz with standard output | |
● on lamp load, max. | 10 Hz | |
Total current of the outputs | ||
● Current per channel, max. | 2 A | |
● Current per group, max. | 4 A | |
● Current per module, max. | 4 A | |
Isochronous mode | ||
Isochronous operation (application synchronized up to terminal) | Yes | |
Bus cycle time (TDP), min. | 250 µs; with 1 channel configuration, 375 µs with 2 channel configuration | |
Jitter, max. | 1 µs; typically ± | |
Interrupts/diagnostics/status information | ||
Diagnostics function | Yes | |
Substitute values connectable | Yes; Parameterizable | |
Alarms | ||
● Diagnostic alarm | Yes | |
Diagnostic messages | ||
● Monitoring the supply voltage | Yes | |
● Short-circuit | Yes | |
Diagnostics indication LED | ||
● Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED | |
● Channel status display | Yes | |
● for module diagnostics | Yes; green/red DIAG LED | |
Potential separation | ||
Potential separation channels | ||
● between the channels | No | |
● between the channels and backplane bus | Yes | |
Permissible potential difference | ||
between different circuits | 75 V DC/60 V AC (base isolation) | |
Isolation | ||
Isolation tested with | 707 V DC (type test) | |
Ambient conditions | ||
Ambient temperature during operation | ||
● horizontal installation, min. | -40 °C; = Tmin; Startup @ -25 °C | |
● horizontal installation, max. | 60 °C; Observe derating | |
● vertical installation, max. | 50 °C; Observe derating | |
Extended ambient conditions | ||
● relative to ambient temperature-atmospheric pressure-installation altitude | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | |
Relative humidity | ||
— With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | |
Resistance | ||
— against biologically active substances / conformity with EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | |
— against chemically active substances / conformity with EN 60721-3-3 | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | |
— against mechanically active substances / conformity with EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | |
Decentralized operation | ||
to SIMATIC S7-300 | Yes | |
to SIMATIC S7-400 | Yes | |
to SIMATIC S7-1200 | Yes | |
to SIMATIC S7-1500 | Yes | |
to standard PROFIBUS master | Yes | |
to standard PROFINET controller | Yes | |
Dimensions | ||
Width | 20 mm | |
Weights | ||
Weight, approx. | 50 g | |
last modified: | 02/01/2017 |