Technická data
Název:
SIPLUS ET 200SP BA 2XFC PN
Popis:
SIPLUS ET 200SP -40 ... +70 GRAD C Startup -25°C WITH CONFORMAL COATING BASEDON 6ES7193-6AF00-0AA0 . BUSADAPTER BA 2XFC, 2X FAST CONNECT ANSCHLUSS FUER PROFINET
Technické informace:
General information | ||
Product type designation | BusAdapter BA 2x FC | |
Interfaces | ||
Number of PROFINET interfaces | 2 | |
PROFINET IO | ||
● FC (FastConnect) | Yes | |
Cable length | ||
— Cu conductors | 100 m | |
Ambient conditions | ||
Ambient temperature during operation | ||
● min. | -40 °C; = Tmin; Startup @ -25 °C | |
● max. | 70 °C; = Tmax | |
Extended ambient conditions | ||
● relative to ambient temperature-atmospheric pressure-installation altitude | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | |
Relative humidity | ||
— With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | |
Resistance | ||
— against biologically active substances / conformity with EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | |
— against chemically active substances / conformity with EN 60721-3-3 | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | |
— against mechanically active substances / conformity with EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | |
Dimensions | ||
Width | 20 mm | |
Height | 69.5 mm | |
Depth | 59 mm | |
Weights | ||
Weight, approx. | 53 g | |
last modified: | 02/01/2017 |