Technická data
Název:
SIPLUS SM331 8AI
Popis:
SIPLUS S7-300 SM331 8AE -25 ... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7331-1KF02-0AB0 . OPTICALLY ISOLATED, 8 AI, 13 BIT RESOLUTION, U/I/RESISTANCE/PT100, NI100, NI1000, LG-NI1000, PTC / KTY, 66 MS MODULE UPDATE, 1 X 40 PIN
Technické informace:
Input current | ||
from backplane bus 5 V DC, max. | 90 mA | |
Power loss | ||
Power loss, typ. | 0.4 W | |
Analog inputs | ||
Number of analog inputs | 8 | |
● For resistance measurement | 8 | |
permissible input voltage for voltage input (destruction limit), max. | 30 V; 12 V continuous, 30 V for max. 1 s | |
permissible input current for current input (destruction limit), max. | 40 mA | |
Input ranges | ||
● Voltage | Yes | |
● Current | Yes | |
● Thermocouple | No | |
● Resistance thermometer | Yes | |
● Resistance | Yes | |
Input ranges (rated values), voltages | ||
● 0 to +10 V | Yes | |
● Input resistance (0 to 10 V) | 100 kΩ | |
● 1 V to 5 V | Yes | |
● Input resistance (1 V to 5 V) | 100 kΩ | |
● 1 V to 10 V | No | |
● -1 V to +1 V | Yes | |
● Input resistance (-1 V to +1 V) | 100 kΩ | |
● -10 V to +10 V | Yes | |
● Input resistance (-10 V to +10 V) | 100 kΩ | |
● -2.5 V to +2.5 V | No | |
● -250 mV to +250 mV | No | |
● -5 V to +5 V | Yes | |
● Input resistance (-5 V to +5 V) | 100 kΩ | |
● -50 mV to +50 mV | Yes | |
● Input resistance (-50 mV to +50 mV) | 100 kΩ | |
● -500 mV to +500 mV | Yes | |
● Input resistance (-500 mV to +500 mV) | 100 kΩ | |
● -80 mV to +80 mV | No | |
Input ranges (rated values), currents | ||
● 0 to 20 mA | Yes | |
● Input resistance (0 to 20 mA) | 100 Ω | |
● -10 mA to +10 mA | No | |
● -20 mA to +20 mA | Yes | |
● Input resistance (-20 mA to +20 mA) | 100 Ω | |
● -3.2 mA to +3.2 mA | No | |
● 4 mA to 20 mA | Yes | |
● Input resistance (4 mA to 20 mA) | 100 Ω | |
Input ranges (rated values), thermocouples | ||
● Type B | No | |
● Type C | No | |
● Type E | No | |
● Type J | No | |
● Type K | No | |
● Type L | No | |
● Type N | No | |
● Type R | No | |
● Type S | No | |
● Type T | No | |
● Type U | No | |
● Type TXK/TXK(L) to GOST | No | |
Input ranges (rated values), resistance thermometer | ||
● Cu 10 | No | |
● Ni 100 | Yes; Standard/climate | |
● Input resistance (Ni 100) | 100 MΩ | |
● Ni 1000 | Yes | |
● Input resistance (Ni 1000) | 100 MΩ | |
● LG-Ni 1000 | Yes; Standard/climate | |
● Input resistance (LG-Ni 1000) | 100 MΩ | |
● Ni 120 | No | |
● Ni 200 | No | |
● Ni 500 | No | |
● Pt 100 | Yes; Standard/climate | |
● Input resistance (Pt 100) | 100 MΩ | |
● Pt 1000 | No | |
● Pt 200 | No | |
● Pt 500 | No | |
Input ranges (rated values), resistors | ||
● 0 to 150 ohms | No | |
● 0 to 300 ohms | No | |
● 0 to 600 ohms | Yes | |
● Input resistance (0 to 600 ohms) | 100 MΩ | |
● 0 to 6000 ohms | Yes | |
● Input resistance (0 to 6000 ohms) | 100 MΩ | |
Characteristic linearization | ||
● parameterizable | Yes | |
— for resistance thermometer | yes; Pt100 standard/air con.; Ni100 standard/air con.; Ni1000 standard/air con.; LG-Ni1000 standard/air con. | |
Cable length | ||
● shielded, max. | 200 m; max. 50 m at 50 mV | |
Analog value generation for the inputs | ||
Measurement principle | integrating | |
Integration and conversion time/resolution per channel | ||
● Resolution with overrange (bit including sign), max. | 13 bit | |
● Integration time, parameterizable | Yes; 60 / 50 ms | |
● Basic conversion time (ms) | 66 / 55 ms | |
● Interference voltage suppression for interference frequency f1 in Hz | 50 / 60 Hz | |
Encoder | ||
Connection of signal encoders | ||
● for current measurement as 2-wire transducer | Yes; with external supply | |
● for current measurement as 4-wire transducer | Yes | |
● for resistance measurement with two-wire connection | Yes | |
● for resistance measurement with three-wire connection | Yes | |
● for resistance measurement with four-wire connection | Yes | |
Errors/accuracies | ||
Operational error limit in overall temperature range | ||
● Voltage, relative to input range, (+/-) | 0.6 %; +/-0.6% (+/-5 V, 10 V, 1 to 5 V, 0 to 10 V); +/-0.5 % (+/-50 mV, 500 mV, 1 V) @ 0 ... +60 °C; +/-0.7% (+/-5 V, 10 V, 1 to 5 V, 0 to 10 V); +/-0.6% (+/-50 mV, 500 mV, 1 V) @ -25 ... +70 °C | |
● Current, relative to input range, (+/-) | 0.5 %; @ 0 ... +60 °C; +/-0.6% @ -25 ... +70 °C; +/-20 mA, 0 to 20 mA, 4 to 20 mA | |
● Resistance, relative to input range, (+/-) | 0.5 %; @ 0 ... +60 °C; 0.6% @ -25 ... +70 °C; 0 to 6 kohm, 0 to 600 kohm | |
● Resistance thermometer, relative to input range, (+/-) | 1 Kelvin (Pt100, Ni100, climate; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climate); 1.2 Kelvin (Pt100, Ni100, standard) @ 0 ... +60 °C; 1.2 Kelvin (Pt100, Ni100, climate; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climate); 1.4 Kelvin (Pt100, Ni100, standard) @ -25 ... +70 °C | |
Basic error limit (operational limit at 25 °C) | ||
● Voltage, relative to input range, (+/-) | 0.4 %; 0.4% (+/-5 V, 10 V, 1 to 5 V, 0 to 10 V); 0.3% (+/-50 mV, 500 mV, 1 V) | |
● Current, relative to input range, (+/-) | 0.3 %; +/-20 mA, 0 to 20 mA, 4 to 20 mA | |
● Resistance, relative to input range, (+/-) | 0.3 %; 0 to 6 kohms, 0 to 600 kohms | |
● Resistance thermometer, relative to input range, (+/-) | 1 Kelvin (Pt100, Ni100, standard); 0.8 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climatic) | |
Interrupts/diagnostics/status information | ||
Diagnostic functions | No | |
Alarms | ||
● Diagnostic alarm | No | |
● Limit value alarm | No | |
Diagnostic messages | ||
● Diagnostic information readable | No | |
Diagnostics indication LED | ||
● Group error SF (red) | No | |
Potential separation | ||
Potential separation analog inputs | ||
● between the channels and backplane bus | Yes | |
Isolation | ||
Isolation tested with | 500 V DC | |
Standards, approvals, certificates | ||
CE mark | Yes | |
UL approval | Yes; File E239877 | |
FM approval | Yes; CofC 3028431 | |
RCM (formerly C-TICK) | Yes | |
KC approval | Yes | |
EAC (formerly Gost-R) | Yes | |
Railway application | ||
● EN 50121-4 | No | |
● EN 50155 | No | |
Ambient conditions | ||
Ambient temperature during operation | ||
● min. | -25 °C | |
● max. | 70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use | |
Extended ambient conditions | ||
● relative to ambient temperature-atmospheric pressure-installation altitude | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | |
Relative humidity | ||
— With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | |
Resistance | ||
— against biologically active substances / conformity with EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | |
— against chemically active substances / conformity with EN 60721-3-3 | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | |
— against mechanically active substances / conformity with EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | |
Connection method | ||
required front connector | 40-pin | |
Dimensions | ||
Width | 40 mm | |
Height | 125 mm | |
Depth | 117 mm | |
Weights | ||
Weight, approx. | 250 g | |
last modified: | 02/01/2017 |