Technická data
Název:
SIPLUS S7-1500 CPU 1513-1 PN
Popis:
SIPLUS S7-1500 CPU 1513-1 PN -40 ... +70 Degrees C Sartup -20 Degrees C with conformal coatingf Based on 6ES7513-1AL01-0AB0 . Central processing unit with working Memory 300 KB for Program and 1.5 MB for data, 1. Interface: PROFINET IRT with 2 port switch, 40 NS Bit-performance, SIMATIC Memory card necessary
Technické informace:
General information | ||
Product type designation | CPU 1513-1 PN | |
HW functional status | FS01 | |
Firmware version | V1.8 | |
Engineering with | ||
● STEP 7 TIA Portal configurable/integrated as of version | V13 SP1 Update 4 | |
Configuration control | ||
via dataset | Yes | |
Display | ||
Screen diagonal (cm) | 3.45 cm | |
Control elements | ||
Number of keys | 6 | |
Mode selector switch | 1 | |
Supply voltage | ||
Type of supply voltage | 24 V DC | |
permissible range, lower limit (DC) | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | |
Reverse polarity protection | Yes | |
Mains buffering | ||
● Mains/voltage failure stored energy time | 5 ms | |
Input current | ||
Current consumption (rated value) | 0.7 A | |
Inrush current, max. | 1.9 A; Rated value | |
I²t | 0.02 A²·s | |
Power | ||
Power consumption from the backplane bus (balanced) | 5.5 W | |
Infeed power to the backplane bus | 10 W | |
Power loss | ||
Power loss, typ. | 5.7 W | |
Memory | ||
SIMATIC memory card required | Yes | |
Work memory | ||
● integrated (for program) | 300 kbyte | |
● integrated (for data) | 1.5 Mbyte | |
Load memory | ||
● Plug-in (SIMATIC Memory Card), max. | 32 Gbyte | |
Backup | ||
● maintenance-free | Yes | |
CPU processing times | ||
for bit operations, typ. | 40 ns | |
for word operations, typ. | 48 ns | |
for fixed point arithmetic, typ. | 64 ns | |
for floating point arithmetic, typ. | 256 ns | |
CPU-blocks | ||
Number of elements (total) | 2 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements | |
DB | ||
● Number range | 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 | |
● Size, max. | 1.5 Mbyte; For non-optimized block accesses, the max. size of the DB is 64 KB | |
FB | ||
● Number range | 0 ... 65 535 | |
● Size, max. | 300 kbyte | |
FC | ||
● Number range | 0 ... 65 535 | |
● Size, max. | 300 kbyte | |
OB | ||
● Size, max. | 300 kbyte | |
● Number of free cycle OBs | 100 | |
● Number of time alarm OBs | 20 | |
● Number of delay alarm OBs | 20 | |
● Number of cyclic interrupt OBs | 20 | |
● Number of process alarm OBs | 50 | |
● Number of DPV1 alarm OBs | 3 | |
● Number of isochronous mode OBs | 1 | |
● Number of technology synchronous alarm OBs | 2 | |
● Number of startup OBs | 100 | |
● Number of asynchronous error OBs | 4 | |
● Number of synchronous error OBs | 2 | |
● Number of diagnostic alarm OBs | 1 | |
Nesting depth | ||
● per priority class | 24 | |
Counters, timers and their retentivity | ||
S7 counter | ||
● Number | 2 048 | |
Retentivity | ||
— adjustable | Yes | |
IEC counter | ||
● Number | Any (only limited by the main memory) | |
Retentivity | ||
— adjustable | Yes | |
S7 times | ||
● Number | 2 048 | |
Retentivity | ||
— adjustable | Yes | |
IEC timer | ||
● Number | Any (only limited by the main memory) | |
Retentivity | ||
— adjustable | Yes | |
Data areas and their retentivity | ||
Retentive data area (incl. timers, counters, flags), max. | 128 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB | |
Flag | ||
● Number, max. | 16 kbyte | |
● Number of clock memories | 8; 8 clock memory bits, grouped into one clock memory byte | |
Data blocks | ||
● Retentivity adjustable | Yes | |
● Retentivity preset | No | |
Local data | ||
● per priority class, max. | 64 kbyte; max. 16 KB per block | |
Address area | ||
Number of IO modules | 2 048; max. number of modules / submodules | |
I/O address area | ||
● Inputs | 32 kbyte; All inputs are in the process image | |
● Outputs | 32 kbyte; All outputs are in the process image | |
per integrated IO subsystem | ||
— Inputs (volume) | 8 kbyte | |
— Outputs (volume) | 8 kbyte | |
per CM/CP | ||
— Inputs (volume) | 8 kbyte | |
— Outputs (volume) | 8 kbyte | |
Subprocess images | ||
● Number of subprocess images, max. | 32 | |
Hardware configuration | ||
Number of distributed IO systems | 20 | |
Number of DP masters | ||
● Via CM | 6; A maximum of 6 CMs (PROFINET + PROFIBUS) can be inserted in total | |
Number of IO Controllers | ||
● integrated | 1 | |
● Via CM | 6; A maximum of 6 CMs (PROFINET + PROFIBUS) can be inserted in total | |
Rack | ||
● Modules per rack, max. | 32; CPU + 31 modules | |
● Number of lines, max. | 1 | |
PtP CM | ||
● Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots | |
Time of day | ||
Clock | ||
● Type | Hardware clock | |
● Backup time | 6 wk; At 40 °C ambient temperature, typically | |
● Deviation per day, max. | 10 s; Typ.: 2 s | |
Operating hours counter | ||
● Number | 16 | |
Clock synchronization | ||
● supported | Yes | |
● in AS, master | Yes | |
● in AS, slave | Yes | |
● on Ethernet via NTP | Yes | |
Interfaces | ||
Number of PROFINET interfaces | 1 | |
1. Interface | ||
Interface types | ||
● Number of ports | 2 | |
● integrated switch | Yes | |
● RJ 45 (Ethernet) | Yes; X1 | |
Functionality | ||
● PROFINET IO Controller | Yes | |
● PROFINET IO Device | Yes | |
● SIMATIC communication | Yes | |
● Open IE communication | Yes | |
● Web server | Yes | |
● Media redundancy | Yes | |
Interface types | ||
RJ 45 (Ethernet) | ||
● 100 Mbps | Yes | |
● Autonegotiation | Yes | |
● Autocrossing | Yes | |
● Industrial Ethernet status LED | Yes | |
Protocols | ||
Number of connections | ||
● Number of connections, max. | 128; via integrated interfaces of the CPU and connected CPs / CMs | |
● Number of connections reserved for ES/HMI/web | 10 | |
● Number of connections via integrated interfaces | 88 | |
● Number of S7 routing paths | 16 | |
PROFINET IO Controller | ||
Services | ||
— PG/OP communication | Yes | |
— S7 routing | Yes | |
— Isochronous mode | Yes | |
— Open IE communication | Yes | |
— IRT | Yes | |
— MRP | Yes; As MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50 | |
— PROFIenergy | Yes | |
— Prioritized startup | Yes; Max. 32 PROFINET devices | |
— Number of connectable IO Devices, max. | 128; In total, up to 256 distributed I/O devices can be connected via PROFIBUS or PROFINET | |
— Of which IO devices with IRT, max. | 64 | |
— Number of connectable IO Devices for RT, max. | 128 | |
— of which in line, max. | 128 | |
— Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 | |
— Number of IO Devices per tool, max. | 8 | |
— Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data | |
Update time for IRT | ||
— for send cycle of 250 µs | 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive | |
— for send cycle of 500 µs | 500 µs to 8 ms | |
— for send cycle of 1 ms | 1 ms to 16 ms | |
— for send cycle of 2 ms | 2 ms to 32 ms | |
— for send cycle of 4 ms | 4 ms to 64 ms | |
— With IRT and parameterization of "odd" send cycles | Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs) | |
Update time for RT | ||
— for send cycle of 250 µs | 250 µs to 128 ms | |
— for send cycle of 500 µs | 500 µs to 256 ms | |
— for send cycle of 1 ms | 1 ms to 512 ms | |
— for send cycle of 2 ms | 2 ms to 512 ms | |
— for send cycle of 4 ms | 4 ms to 512 ms | |
PROFINET IO Device | ||
Services | ||
— PG/OP communication | Yes | |
— S7 routing | Yes | |
— Isochronous mode | No | |
— Open IE communication | Yes | |
— IRT | Yes | |
— MRP | Yes | |
— PROFIenergy | Yes | |
— Shared device | Yes | |
— Number of IO Controllers with shared device, max. | 4 | |
SIMATIC communication | ||
● S7 communication, as server | Yes | |
● S7 communication, as client | Yes | |
● User data per job, max. | See online help (S7 communication, user data size) | |
Open IE communication | ||
● TCP/IP | Yes | |
— Data length, max. | 64 kbyte | |
— several passive connections per port, supported | Yes | |
● ISO-on-TCP (RFC1006) | Yes | |
— Data length, max. | 64 kbyte | |
● UDP | Yes | |
— Data length, max. | 1 472 byte | |
● DHCP | No | |
● SNMP | Yes | |
● DCP | Yes | |
● LLDP | Yes | |
Web server | ||
● HTTP | Yes; Standard and user-defined pages | |
● HTTPS | Yes; Standard and user-defined pages | |
Further protocols | ||
● MODBUS | Yes; MODBUS TCP | |
Media redundancy | ||
● Switchover time on line break, typ. | 200 ms | |
● Number of stations in the ring, max. | 50 | |
Isochronous mode | ||
Isochronous operation (application synchronized up to terminal) | Yes; With minimum OB 6x cycle of 625 µs | |
Equidistance | Yes | |
S7 message functions | ||
Number of login stations for message functions, max. | 32 | |
Block related messages | Yes | |
Number of configurable alarms, max. | 5 000 | |
Number of simultaneously active alarms in alarm pool | ||
● Number of reserved user alarms | 300 | |
● Number of reserved alarms for system diagnostics | 100 | |
● Number of reserved alarms for Motion Control technology objects | 80 | |
Test commissioning functions | ||
Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 5 engineering systems | |
Status block | Yes; Up to 8 simultaneously (in total across all ES clients) | |
Single step | No | |
Status/control | ||
● Status/control variable | Yes | |
● Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters | |
● Number of variables, max. | ||
— of which status variables, max. | 200; per job | |
— of which control variables, max. | 200; per job | |
Forcing | ||
● Forcing, variables | Peripheral inputs/outputs | |
● Number of variables, max. | 200 | |
Diagnostic buffer | ||
● present | Yes | |
● Number of entries, max. | 1 000 | |
— of which powerfail-proof | 500 | |
Traces | ||
● Number of configurable Traces | 4; Up to 512 KB of data per trace are possible | |
Interrupts/diagnostics/status information | ||
Diagnostics indication LED | ||
● RUN/STOP LED | Yes | |
● ERROR LED | Yes | |
● MAINT LED | Yes | |
● Connection display LINK TX/RX | Yes | |
Supported technology objects | ||
Motion Control | Yes | |
● Speed-controlled axis | ||
— Number of speed-controlled axes, max. | 6; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool | |
● Positioning axis | ||
— Number of positioning axes, max. | 6; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool | |
● Synchronized axes (relative gear synchronization) | ||
— Number of axes, max. | 3; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool | |
● External encoders | ||
— Number of external encoders, max. | 6; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool | |
Controller | ||
● PID_Compact | Yes; Universal PID controller with integrated optimization | |
● PID_3Step | Yes; PID controller with integrated optimization for valves | |
● PID-Temp | Yes; PID controller with integrated optimization for temperature | |
Counting and measuring | ||
● High-speed counter | Yes | |
Ambient conditions | ||
Ambient temperature during operation | ||
● horizontal installation, min. | -40 °C; = Tmin; Startup @ -20 °C | |
● horizontal installation, max. | 70 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off | |
● vertical installation, min. | -40 °C; = Tmin; Startup @ -20 °C | |
● vertical installation, max. | 40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off | |
Ambient temperature during storage/transportation | ||
● min. | -40 °C | |
● max. | 70 °C | |
Extended ambient conditions | ||
● relative to ambient temperature-atmospheric pressure-installation altitude | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | |
Relative humidity | ||
— With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | |
Resistance | ||
— against biologically active substances / conformity with EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | |
— against chemically active substances / conformity with EN 60721-3-3 | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | |
— against mechanically active substances / conformity with EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | |
Configuration | ||
Programming | ||
Programming language | ||
— LAD | Yes | |
— FBD | Yes | |
— STL | Yes | |
— SCL | Yes | |
— GRAPH | Yes | |
Know-how protection | ||
● User program protection/password protection | Yes | |
● Copy protection | Yes | |
● Block protection | Yes | |
Access protection | ||
● Password for display | Yes | |
● Protection level: Write protection | Yes | |
● Protection level: Read/write protection | Yes | |
● Protection level: Complete protection | Yes | |
Cycle time monitoring | ||
● lower limit | adjustable minimum cycle time | |
● upper limit | adjustable maximum cycle time | |
Dimensions | ||
Width | 70 mm | |
Height | 147 mm | |
Depth | 129 mm | |
Weights | ||
Weight, approx. | 430 g | |
Other | ||
Note: | At temperatures below 0 °C legibility may be restricted and representation of dynamic contents may be slower | |
last modified: | 02/01/2017 |