Technická data
Název:
SIPLUS S7-1500 DQ 8X230VAC/5A ST (RELAY)
Popis:
SIPLUS S7-1500 DQ 8X230VAC/5A S -25 ... +60 DEGREE C WITH CONFORMAL COATING BASED ON 6ES7522-5HF00-0AB0 . DIGITAL OUTPUT MODULE DQ 8 X 230VAC/5A,RELAY; 8 CHANNELS IN GROUPS OF 1, 5A PER GROUP; DIAGNOSIS; SUBSTITUTE VALUE
Technické informace:
General information | ||
Product type designation | DQ 8x230 V AC/5 A ST (relay) | |
Product function | ||
● I&M data | Yes; I&M0 to I&M3 | |
Operating mode | ||
● MSO | Yes | |
Supply voltage | ||
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 20.4 V | |
permissible range, upper limit (DC) | 28.8 V | |
Input current | ||
Current consumption, max. | 80 mA | |
Power | ||
Power available from the backplane bus | 0.8 W | |
Power loss | ||
Power loss, typ. | 3 W | |
Digital outputs | ||
Number of digital outputs | 8 | |
Controlling a digital input | possible | |
Switching capacity of the outputs | ||
● on lamp load, max. | 1 500 W; 10 000 operating cycles | |
● Low energy/fluorescent lamps with electronic control gear | 10x 58 W (25 000 operating cycles) | |
● Fluorescent tubes, conventionally compensated | 1x 58 W (25 000 operating cycles) | |
● Fluorescent tubes, uncompensated | 10x 58 W (25 000 operating cycles) | |
Output current | ||
● for signal "1" rated value | 5 A | |
● for signal "1" permissible range, min. | 5 mA; 10 V | |
● for signal "1" permissible range, max. | 8 A; thermal continuous current | |
● for signal "0" residual current, max. | 0 A | |
Parallel switching of two outputs | ||
● for logic links | Yes | |
● for uprating | No | |
● for redundant control of a load | Yes | |
Switching frequency | ||
● with resistive load, max. | 2 Hz | |
● with inductive load, max. | 0.5 Hz | |
● on lamp load, max. | 2 Hz | |
Total current of the outputs | ||
● Current per channel, max. | 8 A; Note derating data in the manual | |
● Current per group, max. | 8 A; Note derating data in the manual | |
● Current per module, max. | 64 A; Note derating data in the manual | |
Relay outputs | ||
● Number of relay outputs | 8 | |
● Rated supply voltage of relay coil L+ (DC) | 24 V | |
● Current consumption of relays (coil current of all relays), max. | 80 mA | |
● external protection for relay outputs | With miniature circuit breaker with characteristic B for: cos φ 1.0: 600 A cos φ 0.5 ... 0.7: 900 A with 8 A Diazed fuse: 1000 A | |
● Contact connection (internal) | No | |
● Size of motor starters according to NEMA, max. | 5 | |
● Number of operating cycles, max. | 4 000 000; see additional description in the manual | |
● Relay approved acc. to UL 508 | Yes; 250 V AC/5 A g.p.; 120 V AC TV-4 tungsten; A300, R300 | |
Switching capacity of contacts | ||
— with inductive load, max. | see additional description in the manual | |
— with resistive load, max. | see additional description in the manual | |
Cable length | ||
● shielded, max. | 1 000 m | |
● unshielded, max. | 600 m | |
Isochronous mode | ||
Isochronous operation (application synchronized up to terminal) | No | |
Interrupts/diagnostics/status information | ||
Diagnostics function | Yes | |
Substitute values connectable | Yes | |
Alarms | ||
● Diagnostic alarm | Yes | |
Diagnostic messages | ||
● Monitoring the supply voltage | Yes | |
● Wire-break | No | |
● Short-circuit | No | |
Diagnostics indication LED | ||
● RUN LED | Yes; Green LED | |
● ERROR LED | Yes; Red LED | |
● Monitoring of the supply voltage (PWR-LED) | Yes; Green LED | |
● Channel status display | Yes; Green LED | |
● for channel diagnostics | No | |
● for module diagnostics | Yes; Red LED | |
Potential separation | ||
Potential separation channels | ||
● between the channels | Yes; Switching of different phases permitted | |
● between the channels, in groups of | 1 | |
● between the channels and backplane bus | Yes | |
● Between the channels and load voltage L+ | Yes | |
Permissible potential difference | ||
between different circuits | 75 V DC/60 V AC (base isolation) between backplane bus and the supply voltage L+; 250 V AC between the channels and the supply voltage L+; 250 V AC between the channels and the backplane bus; 500 V AC between the channels | |
Isolation | ||
Isolation tested with | Between the channels: 2 500 V DC; between the channels and backplane bus: 2 500 V DC; between L+ backplane bus 707 V DC (type test) | |
Ambient conditions | ||
Ambient temperature during operation | ||
● horizontal installation, min. | -25 °C; = Tmin | |
● horizontal installation, max. | 60 °C; = Tmax | |
● vertical installation, min. | -25 °C; = Tmin | |
● vertical installation, max. | 40 °C; = Tmax | |
Extended ambient conditions | ||
● relative to ambient temperature-atmospheric pressure-installation altitude | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) | |
Relative humidity | ||
— With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | |
Resistance | ||
— against biologically active substances / conformity with EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | |
— against chemically active substances / conformity with EN 60721-3-3 | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | |
— against mechanically active substances / conformity with EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | |
Decentralized operation | ||
Fast Startup supported | Yes; 500 ms | |
Dimensions | ||
Width | 35 mm | |
Height | 147 mm | |
Depth | 129 mm | |
Weights | ||
Weight, approx. | 200 g | |
last modified: | 02/01/2017 |