Technická data
Název:
SIPLUS S7-1500 AI 8XU/I/RTD/TC ST
Popis:
SIPLUS S7-1500 AI 8XU/I/RTD/TC -40 ... +70 DEGREES C Startup -25°C WITH CONFORMAL COATING BASED ON 6ES7531-7KF00-0AB0 . ANALOG INPUT MODULE 16 BITS OF RESOLUTION, ACCURACY 0.3 %; 8 CHANNELS IN GROUPS OF 8; COMMON MODE VOLTAGE APPR. 10 V; DIAGNOSIS, PROCESSALARMS INCL. INFEED ELEMENT, SHIELD CLAMP AND SHIELD TERMINAL
Technické informace:
General information | ||
Product type designation | AI 8xU/I/RTD/TC ST | |
HW functional status | E01 | |
Firmware version | V1.0.0 | |
Product function | ||
● I&M data | Yes; I&M0 to I&M3 | |
Engineering with | ||
● STEP 7 TIA Portal configurable/integrated as of version | V12 / V12 | |
● STEP 7 configurable/integrated as of version | V5.5 SP3 / - | |
CiR – Configuration in RUN | ||
Reparameterization possible in RUN | Yes | |
Calibration possible in RUN | Yes | |
Supply voltage | ||
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 20.4 V | |
permissible range, upper limit (DC) | 28.8 V | |
Reverse polarity protection | Yes | |
Input current | ||
Current consumption, max. | 240 mA; with 24 V DC supply | |
Encoder supply | ||
24 V encoder supply | ||
● Short-circuit protection | Yes | |
● Output current, max. | 53 mA | |
Power | ||
Power available from the backplane bus | 0.7 W | |
Power loss | ||
Power loss, typ. | 2.7 W | |
Analog inputs | ||
Number of analog inputs | 8 | |
● For current measurement | 8 | |
● For voltage measurement | 8 | |
● For resistance/resistance thermometer measurement | 4 | |
● For thermocouple measurement | 8 | |
permissible input voltage for voltage input (destruction limit), max. | 28.8 V | |
permissible input current for current input (destruction limit), max. | 40 mA | |
Technical unit for temperature measurement adjustable | Yes; °C/°F/K | |
Input ranges (rated values), voltages | ||
● 1 V to 5 V | Yes | |
● Input resistance (1 V to 5 V) | 100 kΩ | |
● -1 V to +1 V | Yes | |
● Input resistance (-1 V to +1 V) | 10 MΩ | |
● -10 V to +10 V | Yes | |
● Input resistance (-10 V to +10 V) | 100 kΩ | |
● -2.5 V to +2.5 V | Yes | |
● Input resistance (-2.5 V to +2.5 V) | 10 MΩ | |
● -250 mV to +250 mV | Yes | |
● Input resistance (-250 mV to +250 mV) | 10 MΩ | |
● -5 V to +5 V | Yes | |
● Input resistance (-5 V to +5 V) | 100 kΩ | |
● -50 mV to +50 mV | Yes | |
● Input resistance (-50 mV to +50 mV) | 10 MΩ | |
● -500 mV to +500 mV | Yes | |
● Input resistance (-500 mV to +500 mV) | 10 MΩ | |
● -80 mV to +80 mV | Yes | |
● Input resistance (-80 mV to +80 mV) | 10 MΩ | |
Input ranges (rated values), currents | ||
● 0 to 20 mA | Yes | |
● Input resistance (0 to 20 mA) | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC | |
● -20 mA to +20 mA | Yes | |
● Input resistance (-20 mA to +20 mA) | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC | |
● 4 mA to 20 mA | Yes | |
● Input resistance (4 mA to 20 mA) | 25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC | |
Input ranges (rated values), thermocouples | ||
● Type B | Yes | |
● Input resistance (Type B) | 10 MΩ | |
● Type E | Yes | |
● Input resistance (Type E) | 10 MΩ | |
● Type J | Yes | |
● Input resistance (type J) | 10 MΩ | |
● Type K | Yes | |
● Input resistance (Type K) | 10 MΩ | |
● Type N | Yes | |
● Input resistance (Type N) | 10 MΩ | |
● Type R | Yes | |
● Input resistance (Type R) | 10 MΩ | |
● Type S | Yes | |
● Input resistance (Type S) | 10 MΩ | |
● Type T | Yes | |
● Input resistance (Type T) | 10 MΩ | |
Input ranges (rated values), resistance thermometer | ||
● Ni 100 | Yes; Standard/climate | |
● Input resistance (Ni 100) | 10 MΩ | |
● Ni 1000 | Yes; Standard/climate | |
● Input resistance (Ni 1000) | 10 MΩ | |
● LG-Ni 1000 | Yes; Standard/climate | |
● Input resistance (LG-Ni 1000) | 10 MΩ | |
● Pt 100 | Yes; Standard/climate | |
● Input resistance (Pt 100) | 10 MΩ | |
● Pt 1000 | Yes; Standard/climate | |
● Input resistance (Pt 1000) | 10 MΩ | |
● Pt 200 | Yes; Standard/climate | |
● Input resistance (Pt 200) | 10 MΩ | |
● Pt 500 | Yes; Standard/climate | |
● Input resistance (Pt 500) | 10 MΩ | |
Input ranges (rated values), resistors | ||
● 0 to 150 ohms | Yes | |
● Input resistance (0 to 150 ohms) | 10 MΩ | |
● 0 to 300 ohms | Yes | |
● Input resistance (0 to 300 ohms) | 10 MΩ | |
● 0 to 600 ohms | Yes | |
● Input resistance (0 to 600 ohms) | 10 MΩ | |
● 0 to 6000 ohms | Yes | |
● Input resistance (0 to 6000 ohms) | 10 MΩ | |
● PTC | Yes | |
● Input resistance (PTC) | 10 MΩ | |
Thermocouple (TC) | ||
Temperature compensation | ||
— external temperature compensation via RTD | Yes | |
— Compensation for 0 °C reference point temperature | Yes; fixed value can be set | |
Cable length | ||
● shielded, max. | 800 m; for U/I, 200 m for R/RTD, 50 m for TC | |
Analog value generation for the inputs | ||
Integration and conversion time/resolution per channel | ||
● Resolution with overrange (bit including sign), max. | 16 bit | |
● Integration time, parameterizable | Yes | |
● Integration time (ms) | 2,5 / 16,67 / 20 / 100 ms | |
● Basic conversion time, including integration time (ms) | 9 / 23 / 27 / 107 ms | |
— additional conversion time for wire-break monitoring | 9 ms | |
— additional conversion time for resistance measurement | 150 ohm, 300 ohm, 600 ohm, Pt100, Pt200, Ni100: 2 ms, 6000 ohm, Pt500, Pt1000, Ni1000, LG-Ni1000, PTC: 4 ms | |
● Interference voltage suppression for interference frequency f1 in Hz | 400 / 60 / 50 / 10 Hz | |
Smoothing of measured values | ||
● parameterizable | Yes | |
● Step: None | Yes | |
● Step: low | Yes | |
● Step: Medium | Yes | |
● Step: High | Yes | |
Encoder | ||
Connection of signal encoders | ||
● for voltage measurement | Yes | |
● for current measurement as 2-wire transducer | Yes | |
— Burden of 2-wire transmitter, max. | 820 Ω | |
● for current measurement as 4-wire transducer | Yes | |
● for resistance measurement with two-wire connection | Yes; Only for PTC | |
● for resistance measurement with three-wire connection | Yes; All measuring ranges except PTC; internal compensation of the cable resistances | |
● for resistance measurement with four-wire connection | Yes; All measuring ranges except PTC | |
Errors/accuracies | ||
Linearity error (relative to input range), (+/-) | 0.02 % | |
Temperature error (relative to input range), (+/-) | 0.005 %/K; with TC type T 0.02 +/- %/K | |
Crosstalk between the inputs, max. | -80 dB | |
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.02 % | |
Temperature error of internal compensation | +/-6 °C | |
Operational error limit in overall temperature range | ||
● Voltage, relative to input range, (+/-) | 0.3 % | |
● Current, relative to input range, (+/-) | 0.3 % | |
● Resistance, relative to input range, (+/-) | 0.3 % | |
● Resistance thermometer, relative to input range, (+/-) | Ptxxx standard: ±1.5 K, Ptxxx climate: ±0.5 K, Nixxx standard: ±0.5 K, Nixxx climate: ±0.3 K | |
● Thermocouple, relative to input range, (+/-) | Type B: > 600 °C ±4.6 K, type E: > -200 °C ±1.5 K, type J: > -210 °C ±1.9 K, type K: > -200 °C ±2.4 K, type N: > -200 °C ±2.9 K, type R: > 0 °C ±4.7 K, type S: > 0 °C ±4.6 K, type T: > -200 °C ±2.4 K | |
Basic error limit (operational limit at 25 °C) | ||
● Voltage, relative to input range, (+/-) | 0.1 % | |
● Current, relative to input range, (+/-) | 0.1 % | |
● Resistance, relative to input range, (+/-) | 0.1 % | |
● Resistance thermometer, relative to input range, (+/-) | Ptxxx standard: ±0.7 K, Ptxxx climate: ±0.2 K, Nixxx standard: ±0.3 K, Nixxx climate: ±0.15 K | |
● Thermocouple, relative to input range, (+/-) | Type B: > 600 °C ±1.7 K, type E: > -200 °C ±0.7 K, type J: > -210 °C ±0.8 K, type K: > -200 °C ±1.2 K, type N: > -200 °C ±1.2 K, type R: > 0 °C ±1.9 K, type S: > 0 °C ±1.9 K, type T: > -200 °C ±0.8 K | |
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency | ||
● Series mode interference (peak value of interference < rated value of input range), min. | 40 dB | |
● Common mode voltage, max. | 10 V | |
● Common mode interference, min. | 60 dB | |
Interrupts/diagnostics/status information | ||
Diagnostics function | Yes | |
Alarms | ||
● Diagnostic alarm | Yes | |
● Limit value alarm | Yes; two upper and two lower limit values in each case | |
Diagnostic messages | ||
● Monitoring the supply voltage | Yes | |
● Wire-break | Yes; Only for 1 to 5 V, 4 to 20 mA, TC, R, and RTD | |
● Overflow/underflow | Yes | |
Diagnostics indication LED | ||
● RUN LED | Yes; Green LED | |
● ERROR LED | Yes; Red LED | |
● Monitoring of the supply voltage (PWR-LED) | Yes; Green LED | |
● Channel status display | Yes; Green LED | |
● for channel diagnostics | Yes; Red LED | |
● for module diagnostics | Yes; Red LED | |
Potential separation | ||
Potential separation channels | ||
● between the channels | No | |
● between the channels, in groups of | 8 | |
● between the channels and backplane bus | Yes | |
● between the channels and the power supply of the electronics | Yes | |
Permissible potential difference | ||
between the inputs (UCM) | 20 V DC | |
Between the inputs and MANA (UCM) | 10 V DC | |
between M internally and the inputs | 75 V DC/60 V AC (base isolation) | |
Isolation | ||
Isolation tested with | 707 V DC (type test) | |
Ambient conditions | ||
Ambient temperature during operation | ||
● horizontal installation, min. | -40 °C; = Tmin; Startup @ -25 °C | |
● horizontal installation, max. | 70 °C; = Tmax; > +60 °C max. 2x ±20 mA or 4x ±10 V or 4x RTD permissible | |
● vertical installation, min. | -40 °C; = Tmin; Startup @ -25 °C | |
● vertical installation, max. | 50 °C; = Tmax | |
Extended ambient conditions | ||
● relative to ambient temperature-atmospheric pressure-installation altitude | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | |
Relative humidity | ||
— With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | |
Resistance | ||
— against biologically active substances / conformity with EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! | |
— against chemically active substances / conformity with EN 60721-3-3 | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | |
— against mechanically active substances / conformity with EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | |
Decentralized operation | ||
Fast Startup supported | No | |
Dimensions | ||
Width | 35 mm | |
Height | 147 mm | |
Depth | 129 mm | |
Weights | ||
Weight, approx. | 310 g | |
Other | ||
Note: | Additional basic error and noise for integration time = 2.5 ms: Voltage: ±250 mV (±0.02%), ±80 mV (±0.05%), ±50 mV (±0.05%); resistance: 150 ohms ±0.02%; resistance thermometer: Pt100 climate: ±0.08 K, Ni100 climate: ±0.08 K; thermocouple: Type B, R, S: ±3 K, type E, J, K, N, T: ±1 K | |
last modified: | 02/01/2017 |